NGL-LJM-4, Hydrocollator Mobile Heating Unit (NGL-LJM-4)

NGL-LJM-4, Hydrocollator Mobile Heating Unit (NGL-LJM-4)

Physical fitness is one thing everyone struggles with today. Especially in this era of white-collar jobs and people are rarely getting enough time to exercise. Most people have resulted in-house exercise and therapeutic exercise.

One of the pieces of equipment helping put healthy path is the hydrocollator pack. And this hydrocollator unit, a tailored design heating tank consists of a thermostatically controlled water bath is where bentonite clay-filled heating packs are kept and heated. This unit is specially designed for warming up hot packs, keeping them warm. It maintains a consistent temperature 158°F to 176°F (70°C–80°C).

The benefits of moist heat therapy over dry heat are well established for pain relief due to arthritis, myofibrils, back pain, muscle strains and spasms.

 

Compare
SKU: Hydrocollator Mobile Heating Unit (NGL-LJM-4) Categories: ,

Description

Hydrocollator Mobile Heating Unit (NGL-LJM-4)

Scientists proved that moist heat packs generate deep moist heat which delivers increased advantages over dry heat to relieve chronic arthritic pain, acute muscle strains and general musculoskeletal discomfort.

Features

These durable stainless steel water tanks house the Hydrocollator moist heat packs.  The units are thermostatically controlled to ensure the ideal therapeutic temperature for the packs. Hydrocollator remains the benchmark heating unit against which other units are judged.

Heats therapy packs and maintains temperature for training rooms, gyms, clinics and physical therapy offices.

Features a wipe clean surface and is constructed of high-quality materials that are durable for long-term use.

  • Effective fiberglass insulation to prevent heat loss
  • Dependable, rugged stainless-steel design
  • Simple to fill with water, no plumbing required
  • Constant temperature of hot packs is maintained
  • Mobile units are equipped with durable swivel, rubber casters for friction free movement

Click for more Hydrocollator Most Heat Pack details >>


Technical Specifications –

  • Power Supply                                     AC 220 V
  • Rated Frequency                                50 Hz
  • Power Consumption                          1500 W
  • Standard Tank Capacity                   115L 
  • Maximum Tank Capacity                 130L
  • Filled Weight                                      110 Kg
  • Temperature  (preset)                    70℃-80℃
  • Heating Up Time to                          70℃ – Around 5 Hours
  • Cool Down Time From                      70℃ – Around 3 Hours
  • Safety Class                                        Class A, Type B
  • Dimensions:                                       89 cm H x 85 cm L x 50 cm W
  • Net Product Weight                          43Kg
  • Gross Product Weight                      75Kg
  • Product material                               Stainless Steel 304

This NGL-LJM-4 mobile Heating Unit is to supply with 24 standard moist heat packs.


Click to download the User Manual>>


Safety Precautions

DO NOT operate this unit in an environment where other devices are being used that intentionally radiates electromagnetic energy in an unshielded manner. Portable and mobile RF communications equipment can affect medical electrical equipment.

The Hydrocollator Heating Unit generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to other devices in the vicinity. Harmful interference to other devices can be determined by turning the Hydrocollator Heating Unit on and off.  


  • The water temperature in the Hydrocollator Heating Unit is approximately 60° F (71° C), and the water scalding temperature is approximately 120° F (49° C).
  • Care must be taken when operating the Hydrocollator Heating Unit adjacent to or stacked with other equipment.
  • The Hydrocollator Heating Unit should be placed on a smooth, level surface. The surface should support up to the Filled Weight (weight of heating unit filled with water).
  • Do not need to adjust the thermostat. The temperature of the Unit has been preset at 70° C to 80 ° C to the best for moist heat pack condition. The temperature of the water should be checked with a thermometer after every adjustment, before using the hot pack. Always allow sufficient time for the water temperature to stabilize.
  • The Hydrocollator Heating Unit should not be installed above a surface that is susceptible to casual water damage.
  • Always keep the water level over the top of the hot packs to avoid burning or scorching of the packs.
  • Always destroy and replace hot packs which are exposed to contamination – hazardous or cleaning materials, bodily fluids, mold, etc.
  • Check water level daily as it has a natural loss due to evaporation.
  • Clean the tank as described in the maintenance portion of at least every 2 weeks.
  • Check unit periodically for signs of leaking and contact service if leaks are noted.
  • Always replace hot packs as soon as they show signs of wear.
  • If the unit is to be left unattended for a period of time, unplug the unit, remove the packs, empty the water, and clean the tank.
  • Do not move the Heating Unit while filled with heated water. Tipping over could result in burns to the user or others.
  • Always unplug the Heating Unit from the power source before attempting to empty water from unit.
  • This unit should be operated, transported, and stored in temperatures between 0° F and 140° F (-18° C and 60° C) and with relative humidity ranging from 10% – 100%.

Care for Use – 

Follow these simple steps to ensure that the Hydrocollator Heating Unit remains in good condition.

  • Excessive chlorine can be detrimental to the stainless steel in the Hydrocollator Heating Unit. No bleach or any cleaner with high chlorine content should be used under any circumstance.
  • Clean regularly for optimal service and operation.
  • Fill daily with water. Water is constantly lost during operation due to evaporation.
  • Chlorine in regular tap water may be present in high enough concentrations to damage the unit. If you suspect high levels of chlorine are detected in the Hydrocollator Heating Unit, the addition of a dechlorinated agent is recommended.
  • Certain additives (such as herbal teas, essential oils, etc.) will damage the hot packs and components of the heating unit, including the stainless steel.
  • The Hydrocollator Heating Unit was designed to heat water and hot packs only.
  • Inspect heating element for pitting and other visible damage during regular cleaning intervals.
  • Inspect power cord for wear, fraying, and other visible damage during regular cleaning intervals.
  • Not recommend the Unit be moved while filled with heated water. Tipping over could result in a burn to the user or others. If the Hydrocollator must be moved while filled, it is strongly recommended to allow the water to cool below 120° F (49° C) before moving the unit.
  • Always unplug the Hydrocollator Heating Unit from the power source before attempting to empty water from unit.

Care of Moist Heat Packs on Hydrocollator Unit   – 

  • Always return the packs to the hot water of the heating unit after each treatment. There it is heated, kept clean, and ready for immediate use. The packs may be boiled; however, this hastens the deterioration of the pack. The pack may also be cleaned by scrubbing the pack with soap and water.
  • A simplified method of keeping the pack clean is to keep it immersed in water. Never allow the hot packs to dry after use.
  • When the pack begins to wear out, the filler oozes and leaks through the fabric of the cloth; sections of the pack appear to be loose and empty and will not retain heat properly. The pack should be replaced when it reaches this state.

Your trusted products!
Apart from healthcare products, we also handle sporting items and paper stationery products. Please refer to our another website for more details: www.novetecgroup.com

 

You may also like…

X